Illustrative view of an interurban road at dusk, with rows of bronze V5700 luminaires mounted on the top of the poles.

Public lighting

Road lighting

A road is lit for what happens on it: junctions, slip roads, accesses and the continuity of the route. The project starts from the road, not from the catalogue.

The starting point

The road sets the rules.

Before choosing a luminaire, the project looks at the route, the junctions and what lies on either side. Light is distributed over that geometry, not over a pretty picture.

  • Route
  • Junctions
  • Maintenance
Illustrative view of the grey V5900 road luminaire, mounted by its side spigot on the arm of a pole beside the road.

What is lit

The carriageway is the starting point, not the only one. Junctions, slip roads, changes of gradient and stretches with accesses determine where light is needed and how it should be distributed.

The surroundings matter too: verges, footways and the routes that share the space with the road. Lighting only the centre of the carriageway leaves the edges unresolved.

What the project decides

The route and the cross-section set the rules. Width, central reservation, alignments and obstacles define where luminaires can go and how the light is aimed.

Uses, operating hours and maintenance come next. A solution that cannot be inspected or replaced easily ends up weighing more than any last-minute adjustment.

Illustrative view of a street at dusk, showing the carriageway, footways and houses.
The stretch, up close.

Light changes with the road section: an open stretch is not the same as a junction or a slip road.

How it is approached

The context is gathered first: a plan or sketch, the intended uses, the constraints already known and the state of any existing installation. Alternatives are then compared and taken through the checks the project requires.

The conversation starts before a solution is fixed. Comparing scenarios and reviewing what each one implies avoids decisions that can no longer be corrected without works.

What to avoid

  • Lighting the whole platform by default, settling the project with a single image and closing the solution without a maintenance plan are the three most expensive shortcuts.
  • An illustrative visual is not a study. If the project needs defined levels, geometry and limits, they have to be requested and reviewed before deciding.

From the catalogue to the road.

Real Conalux catalogue pages. The choice is defined with the project's technical team.

Explore Conalux solutions

Your site. Its uses. The starting point.

Local authorities, lighting consultants and developers: explore Conalux’s solutions and project support to prepare your lighting brief.

  1. Context, plan and uses

    Gather the site context, an available plan and the uses that need to be considered.

  2. Lighting criteria

    Set out routes, surroundings, operating hours and comfort expectations to examine.

  3. Solutions to validate

    Compare possible directions and take them through the necessary project validations before deciding.

Frequently asked questions

What information should be gathered to start?

A plan or sketch of the road, the intended uses, the accesses and the constraints already known. If an installation exists, its condition and maintenance points as well.

Can it be planned for an existing road?

Yes, starting from the existing installation and its constraints on access, supports and maintenance. Feasibility and the solution are defined case by case.

What is the difference between a visual and a study?

A visual illustrates an idea. A study starts from calculation assumptions, geometry, criteria and the limits of the area analysed, and can be reviewed.

From plan to solution

Conalux brings together the solutions and advice to prepare your road lighting project.

Explore Conalux solutions
← See all projects